Temperature setting range +25°C … +100°C
Temperature control range 5°C above ambient … +100°C
Temperature setting resolution 0.1°C
Temperature stability ±0.1°C
Temperature accuracy at +37°C ±0.5°C
Average heating speed from +25°C to +100°C 4°C/min
Temperature uniformity over the block at +37°C ±0.1°C
Temperature uniformity over the block at +100°C ±0.2°C
Temperature calibration coefficient range 0.936…1.063 (± 0.063)
Speed control range 250–1400 rpm
Digital time setting 1 min–96 hrs (1 min increment)
Timer sound signal +
Orbit 2 mm
Display LCD, 16 x 2 signs
Microprocessor controlled temperature, mixing speed and operation time +
Maximum continuous operation time 168 h
Overall dimensions (W×D×H) 220x240x90 mm
Weight 3.7 kg
Input current/power consumption 12 V, 3.5 A / 42 W
قارن Report Abuse

Thermo–Shaker TS-100 provides intensive mixing and temperature control of samples in microtest tubes or PCR plate. Functions of heating (up to +100°C) and mixing can be performed both simultaneously and independently, i.e. the unit implements three devices in one:

1. Shaker;
2. Dry–block Thermostat;
3. Thermo–Shaker.

TS-100 is used for DNA analysis sample preparation, for extraction of proteins, polysaccharides, lipids and other cellular components. Features of TS-100 meet the increased requirements of the user, including:

  • Quickly reaches the set mixing speed and maintains same amplitude of rotation around the block;
  • Stable maintenance of the temperature of a wide range over the entire surface of the block;
  • LCD display shows the set and actual temperature, speed and time;
  • Quiet engine operation, compact size, long service life.

Heating source is a printed heating board (12 V). Mixing is provided by movement of orbital type.

The instrument is applicable in:

  • Genetic analysis — in extraction of DNA, RNA and further sample preparation;
  • Biochemical study of enzymatic reactions and processes;
  • Extraction of metabolites from cellular material.

Temperature Calibration Function

With the help of the temperature calibration function the user can calibrate the unit approx. ±6% of the selected temperature to compensate differences in the thermal behaviour of tubes from different manufacturers