Parameters Cat No. Cat No.
Amplification Factor 2.5×, 5 mega-pixel
Focus Method Manual focusing & Autofocusing (less than 3s)
Counting Area 2.15 mm×1.62 mm
Fluorescence Application PI(Ex:540/25nm; Em:620/60 nm)
DAPI(Ex:375/28nm; Em:460/50nm)
AO/GFP(Ex:480/30nm; Em:535/40nm)
Cell Type Cell lines, stem cells, primary cells
Cell Size Range 4-60 μm (Optimal: 7-60 μm)
Cell Concentration Range 10 – 10 cells/mL
Cell Counting Time Less than 9s
Historical Data Storage 1000 counting reports and images at most
Languages Chinese and English
Dimensions (W×D×H) 212 mm(W)* 264 mm(H)* 165 mm (D)
Weight 3.2 kg
قارن Report Abuse

A Real Time-Saver Speeds up Your Research

RWD C-100 automated cell counter is a reliable cell counting devices with highly intelligent analysis software and excellent microscopy optics structure. It can realize accurate, safe cell-counting, and fluorescence analysis in 9 seconds and fast counting mode takes 3s only, which liberates researchers from the heavy work of daily cell counting.

 

RWD C100 Automatic Cell Counter Realizes Analysis With Multiple Application Scenarios

Cell Count Analysis: C100 is suitable for counting cells or particles with a diameter of 4-60μm, such as most cell lines, stem cells, primary cells, etc.

Cell Viability Analysis: When testing cell viability in trypan blue mode, after staining, live cells will be circled in green, and dead cells will be circled in red.

Cell Size Analysis: In cell research, cell size is a key feature, which is often measured in cell transfection, drug testing and cell viability.

After counting, C100 will count the average diameter of the cells in the sample and automatically generate a histogram.

Cell Fluorescence Analysis:

Detect Cell Transfection Efficiency (GFP, RFP):

When transfecting cells with the target gene, the transfection efficiency needs to be evaluated. In general, the transfected plasmid has the sequence encoding the fluorescent protein as the reporter gene, so the successfully transfected cell should be positive for the fluorescent protein. In addition, using a fluorescence microscope or a flow cytometer is a commonly used method for transfection efficiency analysis in laboratories, but both have the disadvantages of complicated operation and high cost. Using the fluorescence analysis function of C100, equipped with the corresponding fluorescence module, can realize the analysis of the expression of GFP, RFP, and other fluorescent proteins, and automatically count them, so as to quickly, simply, and efficiently obtain the positive rate of target gene expression.

Cell Fluorescence Analysis:

Cell Viability Identification (AO/PI Dual Fluorescence Method).
In addition to trypan blue staining, AO/PI dual fluorescence staining has become popular as a more accurate live cell counting method and is widely used for primary cell counting.